2 possible causes and remedies, Profibus: no memory access [0x00c85531, Profibus: read memory error [0x00c85532 – Lenze E94AYCPM User Manual

Page 88: Profibus: write memory error [0x00c85533, Profibus: restart after watchdog reset [0x00c86010, Possible causes and remedies, 0x00c83100, 0x00c85531, 0x00c85532, 0x00c85533

Advertising
background image

13

Error messages

13.2

Possible causes and remedies

88

Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.2

Possible causes and remedies

This chapter lists all PROFIBUS error messages in the numerical order of the error numbers. Possible

causes and remedies as well as responses to the error messages are described in detail.

Profibus: Lost connection to 9400 standard device [0x00c83100]

Profibus: No memory access [0x00c85531]

Profibus: Read memory error [0x00c85532]

Profibus: Write memory error [0x00c85533]

Profibus: Restart after watchdog reset [0x00c86010]

Response (Lenze setting printed in bold)

Setting: not possible

:

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

• Network cable (plug) is defective.

• Network cable is not connected to the PROFIBUS

terminal X201.

• Voltage supply is interrupted.

Check cables and terminals.

Connect network cable to the PROFIBUS terminal X201.

Response (Lenze setting printed in bold)

Setting: not possible

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

Access to memory was not possible.

Repeat the download of the application

(including module)

Response (Lenze setting printed in bold)

Setting: not possible

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

Parameter could not be read.

Repeat the download of the application

(including module)

Response (Lenze setting printed in bold)

Setting: not possible

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

Parameter could not be written.

Repeat the download of the application

(including module)

Response (Lenze setting printed in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Module defective.

If this occurs repeatedly, contact the Lenze service.