19

4

Technical data

4.3

Protocol data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.3

Protocol data

4.4

Communication time

The communication time is the time between the start of a request and the arrival of the

corresponding response.
The communication times in a PROFIBUS network depend on ...

• the processing time in the controller;
• the transmission delay time (baud rate / telegram length);
• the nesting depth of the network.

Processing time in the controller

There are no interdependencies between parameter data and process data.

Area

Values

Process data words (PCD)

1 ... 32 words (16 bits/word)

Cyclic parameter data channel (DP-

V0)

4 words

Acyclic parameter data channel (DP-

V1)

Max. 240 bytes

Safety data

4 words

PROFIBUS user data length

1 ... 32 words (process data)

+ 4 words (parameter data or safety data)

Data

Processing time

Process data

Approx. 4 ms

+ 0 ... 1 ms

+ 1 ... x ms

update cycle

processing time in the module

application task runtime of the technology application used

(tolerance)

Parameter data

Approx. 30 ms + 20 ms tolerance (typical)

For some codes, the processing time may be longer (see software manual/

online help for the Servo Drive 9400).