C14855 | com word from standard device, C14860 | settings, C14861 | bus status – Lenze E94AYCPM User Manual

Page 104: C14862 | bus counter, C14861, Indica, 14 parameter reference

Advertising
background image

14

Parameter reference

14.3

Parameters of the communication module for slot MXI2

104

Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14855

C14860

C14861

C14862

Parameter | Name:

C14855 | COM word from standard device

Data type: BITFIELD_32

Index: 9720

d

= 25F8

h

Available from software version 01.21!

This code is for device-internal use only and must not be overwritten by the user!

Parameter | Name:

C14860 | Settings

Data type: UNSIGNED_8

Index: 9715

d

= 25F3

h

Display of the current configuration data.
Display area

(min. value | unit | max. value)

0

255

Subcodes

Info

C14860/1

PROFIsafe

• 0: Not active

• 1: Active

C14860/2

Number of process data words (1 ... 32 words)

C14860/3

DRIVECOM parameter data channel

• 0: Not active

• 1: Active

C14860/4

Number of PROFIsafe words (0 or 4 words)

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C14861 | Bus status

Data type: UNSIGNED_16

Index: 9714

d

= 25F2

h

Bit-coded display of the current bus state.



Querying the current bus status ( 84)

Display area

(min. value | unit | max. value)

0

65535

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C14862 | Bus counter

Data type: UNSIGNED_16

Index: 9713

d

= 25F1

h

When the maximum count value of 65535 is reached, the counter starts again with 0.
Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C14862/1

Data cycles per second

C14862/2

Total data cycles

C14862/3

Total parameterisation events

C14862/4

Total configuration events

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT