14 parameter reference, C00615 | resp. to imp. device conf, C00636 | resp. to new module in mxi1 – Lenze E94AYCPM User Manual

Page 91: Parameter reference

Advertising
background image

Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17

91

14

Parameter reference

14.1

Communication-relevant parameters of the standard device

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14

Parameter reference

This chapter supplements the parameter list and the table of attributes contained in the software

manual and in the »Engineer« online help for the Servo Drive 9400 with the parameters of the

E94AYCPM (PROFIBUS) communication module.

14.1

Communication-relevant parameters of the standard device

This chapter lists the communication-relevant parameters of the Servo Drive 9400 in numerically

ascending order.

C00615

C00636

Software manual/»Engineer« online help for Servo Drive 9400
Here you can find general information on parameters.

Parameter | Name:

C00615 | Resp. to imp. device conf.

Data type: UNSIGNED_32

Index: 23960

d

= 5D98

h

Response to incorrect device configuration
Selection list

1 Error
3 Quick stop by trouble
4 Warning locked
6 Information
0 No response

Subcodes

Lenze setting

Info

C00615/1

0: No response

Reserved

C00615/2

1: Fault

Resp. to imp. module in MXI1

C00615/3

1: Fault

Resp. to imp. module in MXI2

C00615/4

0: No response

Reserved

C00615/5

0: No response

Reserved

;

Read access ; Write access … CINH … PLC-STOP … No transfer

Parameter | Name:

C00636 | Resp. to new module in MXI1

Data type: UNSIGNED_32

Index: 23939

d

= 5D83

h

Response when a new module has been inserted in module slot 1 of the standard device.
Selection list

(Lenze setting printed in bold)

1 Error
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

;

Read access ; Write access … CINH … PLC-STOP … No transfer