C14897 | profisafe: target address, C14899 | station address, C14900 | firmware product type – Lenze E94AYCPM User Manual

Page 109: C14901 | firmware compilation date, C14902 | firmware version, C14899, 14 parameter reference

Advertising
background image

Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17

109

14

Parameter reference

14.3

Parameters of the communication module for slot MXI2

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14897

C14899

C14900

C14901

C14902

Parameter | Name:

C14897 | PROFIsafe: Target address

Data type: UNSIGNED_16

Index: 9678

d

= 25CE

h

Setting of the PROFIsafe target address

• Only required if the SM301 (E94AYAE) safety module is used.

• A unique PROFIsafe target address must be assigned to each controller.

Einstellbereich

(min. Wert | Einheit | max. Wert)

Lenze setting

1

65534 1

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX ; COM … MOT

Parameter | Name:

C14899 | Station address

Data type: UNSIGNED_8

Index: 9676

d

= 25CC

h

Optional setting of the station address (instead of setting via DIP switches 1 ... 64)

• The station address set here only becomes effective if the DIP switches 1 ... 64 have been set to OFF prior to mains

switching.

• The active station address is displayed under

C14864

.

Note: A change of the station address will not be effective until the " Save parameter set" device command has been

executed and another mains switching for the communication module/controller has been performed.



Setting the station address ( 31)

Einstellbereich

(min. Wert | Einheit | max. Wert)

Lenze setting

3

126 3

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX ; COM … MOT

Parameter | Name:

C14900 | Firmware product type

Data type: VISIBLE_STRING

Index: 9675

d

= 25CB

h

Display of the product type (string with a length of 8 bytes)

The following identification code is displayed: "E94AFCPM".

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C14901 | Firmware compilation date

Data type: VISIBLE_STRING

Index: 9674

d

= 25CA

h

Display of the compilation date of the firmware (string with a length of 20 bytes)

The date ("MMM DD YYYY") and time ("hh:mm:ss") are displayed, e.g. "Mar 21 2005 12:31:21".

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C14902 | Firmware version

Data type: VISIBLE_STRING

Index: 9673

d

= 25C9

h

Display of the firmware version (string with a length of 5 bytes)

Example: "01.21"

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT