3 features, Features, 3product description – Lenze E94AYCPM User Manual

Page 13

Advertising
background image

Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17

13

3

Product description

3.3

Features

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.3

Features

• Interface module for the PROFIBUS communication system to be connected to the expansion

slots of the Servo Drives 9400

• Support of parameter data channels DRIVECOM (DP-V0) and PROFIDrive (DP-V1)
• Transfer of safe information via the PROFIsafe protocol if an SM301 safety module (E94AYAE) is

used simultaneously

• A maximum of 32 process data words per direction can be exchanged.
• The communication module can either be supplied internally by the Servo Drive 9400 or

externally by a separate voltage source.

• Bus coupling via remote bus according to the RS485 standard
• Automatic detection of the baud rate (9.6 kbps to 12 Mbps)
• Setting of the station address is possible via DIP switch or code.
• Software compatibility with the EMF2133IB communication module
• Access to all Lenze parameters