59

9

Parameter data transfer

9.3

PROFIdrive parameter data channel (DP-V1)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.3.2

Acyclic data transfer

[9-3]

Transmission directions

Explanation

• A "Write.req" is used to pass the data set (DB47) to the slave in the form of a parameter request.
• With "Write.res" the master receives the confirmation for the receipt of the message.
• The master requests the response of the slave with "Read.req".
• The slave responds with "Read.res (-)" if processing has not yet been completed.
• After parameter processing, the parameter request is completed by transmitting the parameter

response to the master with "Read.res (+)".

Note!

A parameter request refers to one or several parameter(s) (multi-parameter request).

E94YCPM011

Master

Slave

DP-V1

Write.res

Write.req

with data (parameter request)

with data (parameter response)

without data

without data

without data

without data

Read.req

Read.res (-)

Read.req

Read.res (+)

Parameter response

Parameter request

Parameter request

Parameter
processing

Parameter response