Technical data

4.1

General data and operating conditions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4

Technical data

4.1

General data and operating conditions

"Servo Drives 9400" Hardware Manual
Here you can find the ambient conditions and information on the electromagnetic

compatibility (EMC) which also apply to the communication module.

Area

Values

Order designation

E94AYCPM

Communication profile

• PROFIBUS DP-V0 (DRIVECOM)

• PROFIBUS DP-V1 (PROFIdrive)

Communication medium

RS485

Interface

9-pin Sub-D socket

Network topology

• Line (without repeater)

• Tree/line (with repeater)

Bus device type

PROFIBUS slave

Number of slaves

• Max. 31 (without repeater)

• Max. 125 (with repeater)

Max. cable length

1200 m (depending on the selected baud rate and the cable type used)

PNO identification number

0x07A8

Baud rate for cable type A (EN 50170) 9.6 kbps ... 12 Mbps (automatic detection)
Voltage supply

External supply via the 2-pin plug connector

• Terminal "+": U = 24 V DC (20.4 V - 0 % ... 28.8 V + 0 %), I = 130 mA

• Terminal "-": Reference potential for external voltage supply

Conformities, approvals

• CE

• UL