Technical data

General data

4

l

15

EDS82ZAFVCxxx EN 4.0

4

Technical data

4.1

General data

Field

Values

Communication profile

DeviceNet

Communication medium

DIN ISO 11898

Network topology

Line terminated at both ends (R = 120 Ohms)

Max. number of devices

63

DeviceNet device

Slave

Baud rate [kbit/s]

125, 250, 500

Achievable bus cable length

Depending on the cable used, see

^ 28

External voltage supply

See

^ 24

4.2

Operating conditions

Ambient conditions

Climate

Storage

IEC/EN 60721−3−1

1K3 (−25 to +60 °C)

Transport

IEC/EN 60721−3−2

2K3 (−25 to +70 °C)

Operation

Corresponding to the data of the Lenze standard device used (see documentation
of the standard device).

Pollution

EN 61800−5−1

Degree of pollution 2

Degree of protection

IP20 (protection against accidental contact according to NEMA 250 type 1)