C1518:
I/O data length
Code
Subcode
Possible settings
Data type
Lenze
Selection
C1518
−
4
1
[1]
12
FIX32
This code determines the number of words (I/O input data and I/O output data) being
currently exchanged with the scanner.
A change of the I/O data length must be sent to the scanner via the configuration program.
C1519:
Behaviour in idle state/in case of an error
Code
Subcode
Possible settings
Data type
Lenze
Selection
C1519
/1 ... /3
0
0
[1]
3
FIX32
Subcode
Meaning
1
Setting of the reaction in the event of idle running of the DeviceNet communication.
2
Setting of the reaction if the communication is interrupted (time out)
3
Setting of the reaction if a bus error occurs (duplicate MAC-ID, Bus−Off).
Selection
Baud rate
0
No action
1
Fault (TRIP)
2
Controller inhibit
3
Quick stop
C1520:
Display of all words to scanner
Code
Subcode
Possible settings
Data type
Lenze
Selection
C1520
/1 ... /12
g
0
[1]
65535 U16
Display of the process data input words PEW1 to PEW12 in the corresponding subcodes.
C1521:
Display of all words from scanner
Code
Subcode
Possible settings
Data type
Lenze
Selection
C1521
/1 ... /12
g
0
[1]
65535 U16
Display of the process data output words 1 ... 12 of the scanner in the corresponding
subcodes.