Codes 8 – Lenze E82ZAFVC010 User Manual

Page 52

Advertising
background image

Codes

8

l

52

EDS82ZAFVCxxx EN 4.0

C1566:
Automatic trip reset communication error

Code

Subcode

Possible settings

Data type

Lenze

Selection

C1566

0

0 / 1

FIX32

Selection

Meaning

0

No trip reset

1

One−time trip reset of communication monitoring to the basic device

The recommended switch−on sequence is as follows:

1. Switch on DeviceNet

2. Switch on the basic device

If the order is reversed, a communication error is indicated.

With code C1566 = 1, this message is always automatically reset once after switching on
the DeviceNet supply voltage.

)

Note!

If the software is compatible with the E82ZAFD function module (DIP switch
S10), this function is not active.

Advertising