Codes

8

l

49

EDS82ZAFVCxxx EN 4.0

C1522:
Display of all process data words to the basic device

Code

Subcode

Possible settings

Data type

Lenze

Selection

C1522

1...16

g

0

[1]

65535 U16

Display of the process data words 1 ... 16, which are transferred from the function module
to the basic device:

Subcode

Process data word

1 FIF control word 1 (FIF−CTRL1)

2 FIF control word 2 (FIF−CTRL2)

3 Setpoint 1 (NSET1−N1)

4 Setpoint 2 (NSET1−N2)

5 Additional setpoint (PCTRL1−NADD)

6 Actual process controller value (PCTRL1−ACT)

7 Process controller setpoint (PCTRL1−SET1)

8 Reserved

9 Torque setpoint or torque limit value (MCTRL1−MSET)

10 PWM voltage(MCTRL1−VOLT−ADD)

11 PWM angle (MCTRL1−PHI−ADD)

12 Reserved

13 FIF−IN.W1

14 FIF−IN.W2

15 FIF−IN.W3

16 FIF−IN.W4