Appendix – Lenze E82ZAFVC010 User Manual

Page 59

Advertising
background image

Appendix

Data transfer

Overview of the implemented objects for the function module

9

l

59

EDS82ZAFVCxxx EN 4.0

Connection Class (05

hex

)

Instance 1 (explicit messages):

Attribute

Service(s)

Description

Data type

Value

1

GET

state

USINT

Status of the object

2

GET

instance_type

USINT

0

3

GET

transportClass_
trigger

BYTE

131 (83

hex

)

4

GET

produced_
connection_id

UINT

Send CAN identifier

5

GET

consumed_
connection_id

UINT

Reception of CAN identifier

6

GET

initial_comm_
characteristics

BYTE

33 (21

hex

)

7

GET

produced_
connection_size

UINT

64 (40

hex

)

8

GET

consumed_
connection_size

UINT

64 (40

hex

)

9

GET / SET

expected_
packet_rate

UINT

Connection−dependent

10/11

Not used

No longer defined

12

GET / SET

watchdog_
timeout_action

USINT

Defined reaction to timeout

l

1 = Auto Delete

l

3 = Deferred Delete

13

GET

produced_
connection_
path_length

UINT

0

14

GET

produced_
connection_path

EPATH

−−−

15

GET

consumed_
connection_
path_length

UINT

0

16

GET

consumed_
connection_path

EPATH

−−−

17

GET

production_
inhibit_time

UINT

0

Advertising