Cable cross−sections and screw−tightening torques

Function module E82ZAFVC001

Range

Values

Electrical connection

Terminal strip with screw connection

Possible connections

rigid:

1.5 mm

2

(AWG 16)

flexible:

without wire end ferrule
1.0 mm

2

(AWG 18)

with wire end ferrule, without plastic sleeve
0.5 mm

2

(AWG 20)

with wire end ferrule, with plastic sleeve
0.5 mm

2

(AWG 20)

Tightening torque

0.22 ... 0.25 Nm (1.9 ... 2.2 lb−in)

Bare end

5 mm

Function module E82ZAFVC010

Field

Values

Electrical connection

Plug connector with double screw connection

Possible connections

rigid:

1.5 mm

2

(AWG 16)

flexible:

without wire end ferrule
1.5 mm

2

(AWG 16)

with wire end ferrule, without plastic sleeve
1.5 mm

2

(AWG 16)

with wire end ferrule, with plastic sleeve
1.5 mm

2

(AWG 16)

Tightening torque

0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in)

Stripping length

10 mm

Field

Values

Electrical connection

2−pin plug connector with spring connection

Possible connections

rigid:

1.5 mm

2

(AWG 16)

flexible:

without wire end ferrule
1.5 mm

2

(AWG 16)

with wire end ferrule, without plastic sleeve
1.5 mm

2

(AWG 16)

with wire end ferrule, with plastic sleeve
1.5 mm

2

(AWG 16)

Stripping length

9 mm