Appendix
Data transfer
Overview of the implemented objects for the function module
l
64
EDS82ZAFVCxxx EN 4.0
Manufacturer−specific class 102 (66
hex
)
Instance 0:
Attribute
Service(s)
Description
Data type
Value
1
GET
Revision
UINT
0001
hex
Instance 1:
Attribute
Service(s)
Description
Data type
Value
1
GET / SET
I/O data length
in words
UINT
1 – 12 (0000
hex
– 000C
hex
),
Default: 4, (saved in EEPROM)
Services:
Service code
Name
Description
0E
hex
Get_Attribute_Single
Reading an attribute
10
hex
Set_Attribute_Single
Writing an attribute
)
Note!
ƒ
A change of the I/O data length is reported to the scanner
(produced/consumed data size).
ƒ
If the I/O data length is reduced, it must be checked before, if the intended
data length is sufficient for the application.
ƒ
If the function modules have to be replaced, the machine manufacturer
must provide an application−specific configuration for the end customer
that differs from the Lenze default setting. A parameterisation that deviates
from the Lenze default setting cannot be executed via Lenze engineering
tools.
Manufacturer−specific class 103 (67
hex
)
Instance 0:
Attribute
Service(s)
Description
Data type
Value
1
GET
Revision
UINT
0001
hex
Instance 1:
Attribute
Service(s)
Description
Data type
Value
1
GET
I/O image of the
transmitted data
(input data of the
scanner)
Array of UINT
Value according to the words set
Services:
Service code
Name
Description
0E
hex
Get_Attribute_Single
Reading of an attribute