Appendix

Data transfer
Overview of the implemented objects for the function module

9

l

64

EDS82ZAFVCxxx EN 4.0

Manufacturer−specific class 102 (66

hex

)

Instance 0:

Attribute

Service(s)

Description

Data type

Value

1

GET

Revision

UINT

0001

hex

Instance 1:

Attribute

Service(s)

Description

Data type

Value

1

GET / SET

I/O data length
in words

UINT

1 – 12 (0000

hex

– 000C

hex

),

Default: 4, (saved in EEPROM)

Services:

Service code

Name

Description

0E

hex

Get_Attribute_Single

Reading an attribute

10

hex

Set_Attribute_Single

Writing an attribute

)

Note!

ƒ

A change of the I/O data length is reported to the scanner
(produced/consumed data size).

ƒ

If the I/O data length is reduced, it must be checked before, if the intended
data length is sufficient for the application.

ƒ

If the function modules have to be replaced, the machine manufacturer
must provide an application−specific configuration for the end customer
that differs from the Lenze default setting. A parameterisation that deviates
from the Lenze default setting cannot be executed via Lenze engineering
tools.

Manufacturer−specific class 103 (67

hex

)

Instance 0:

Attribute

Service(s)

Description

Data type

Value

1

GET

Revision

UINT

0001

hex

Instance 1:

Attribute

Service(s)

Description

Data type

Value

1

GET

I/O image of the
transmitted data
(input data of the
scanner)

Array of UINT

Value according to the words set

Services:

Service code

Name

Description

0E

hex

Get_Attribute_Single

Reading of an attribute