4 terminal assignment, Terminal assignment, Installation – Lenze E82ZAFVC010 User Manual

Page 25: Electrical installation terminal assignment, Use the thin" cable to wire the function module

Advertising
background image

Installation

Electrical installation

Terminal assignment

5

l

25

EDS82ZAFVCxxx EN 4.0

5.2.4

Terminal assignment

Function module E82ZAFVC001

Supply of the controller inhibit (CINH) via the internal voltage source (X3/20)

GND1

SH

SH

CH

CH

20

X3

CL

CL

V-

V-

V+

V+

28

39

7

GND2

_

+

E82ZAFD003

Supply of the controller inhibit (CINH) via the external voltage source

GND1

GND2

X3

_

+

SH

SH

CH

CH

20

CL

CL

V-

V-

V+

V+

28

39

7

_

+

E82ZAFD006

Min. wiring required for operation

X3/

Name

Function

Level

V−

Reference potential for external voltage supply

CL

CAN−LOW

CAN data line (LOW)

SH

SHIELD

Shield

CH

CAN−HIGH

CAN data line (HIGH)

V+

External supply voltage

Please observe notes concerning
external supply!

7

GND1

Reference potential for X3/20

39

GND2

Reference potential for controller inhibit (CINH) at X3/28

28

CINH

Controller inhibit

l

Start = HIGH (+12 V ... +30 V)

l

Stop = LOW (0 ... +3 V)

20

DC voltage supply for internal supply of
controller inhibit (CINH)

+20 V (ref.: GND1)

)

Note!

Use the Thin" cable to wire the function module

^ 22

.

Advertising