Software implementation and parameter setting

5.1

Setup menu

In this menu the access authorisations are defined, the operating level is specified, and the

parameters of the RS232 interface are set.
Before the other menu pages can be used, communication with the drive first has to be

established via this menu page. Via the operating level that is selected and permitted in

this menu, the authorisation level or the access authorisations are automatically defined.

pÉíìé

5.1.1

Operating modes

Offline
In this operating mode, the servo inverter is disconnected from the RS232 interface. A

programming process may be effected in the offline status, though for transmission to the

motor has to be saved on the PC by means of ”Save configuration” and be transferred to

the inverter in online operation by means of the function ”Load configuration”.

Online level 1
The system is online from level 1. In this level, however, it can only be observed. This level

serves to analyse the status of the drive system. If the inverter is controlled by means of a

bus system (CAN, Profibus), important data can be observed.