Software implementation and parameter setting

Inputs and outputs menu

Application Box: digital inputs

5

55

HB 13.0001-EN

3.0

The functions of the clearly predefined inputs depend on the type of control (bus system

or IO). They are specified in the following table.

Predefined function

Control via ”Fluxx” or via digital IOs

Control via CAN bus

Control via Profibus

8 BCD-coded inputs (type

930MA140400 only)

The selection of the travel data set is effected

via 8 inputs. For this purpose, the lower 4 inputs

are used in a binary coded manner for the

definition of the first decimal place (0…9), and

the upper four inputs are used in a binary coded

way for the second decimal place (0, 10, 20, …,

90). The travel data set thus selected afterwards

can be started by activating the ”Start” input.

No function

No function

Start

When the input is activated, the travel data set

that is currently selected via the binary coded

inputs of the application box (IP54 box: selected

travel data set = 0) is started. After the start,

also subsequent travel data sets (see next travel

data set on the ”Travel data sets” tab) are

effected.

For starting a travel data set, the edge of the

”Start” input is evaluated.

The ”Start” function can only be used if the

operating modes ”Online level 1” or ”Offline

(Fluxx)” are set.

No function

No function

Stop

In case of an active input signal, the travel

program is stopped irrespectively of the status

of the ”Start” input.

After deactivation of the ”Stop” input, the

selected travel program can be restarted by

activating the ”Start” input.

The ”Stop” function can only be used if the

operating modes ”Online level 1” or ”Offline

(Fluxx)” are set.

No function

No function

Limit switch, left

In case of the reference type ”Limit switch, left”, the digital input is evaluated as a reference. When a

reference run is effected and the limit switch is reached, the home position is set in consideration of

the settings carried out on the ”Reference” tab.

Furthermore, a quick stop is actuated during operation if the limit switch is reached.

Limit switch, right

In case of the reference type ”Limit switch, right”, the digital input is evaluated as a reference. When a

reference run is effected and the limit switch is reached, the home position is set in consideration of

the settings carried out on the ”Reference” tab.

Furthermore, a quick stop is actuated during operation if the limit switch is reached.

Quick stop

If the input is activated, the motor is braked to the speed 0 at maximum permissible torque.

Additionally, the mechanical holding brake engages if the input is activated. Afterwards, the output

stage of the inverter is switched off, and the ”Quick stop” fault is output. Then an actively applied

torque no longer is available on the motor shaft.

After deactivation of the input, the drive can be restarted. For this purpose, an acknowledgement of

the fault is required for an operation via bus systems.

Tab. 5

Functions of the predefined inputs of the function modules