Software implementation and parameter setting – Lenze 931W User Manual

Page 67

Advertising
background image

Software implementation and parameter setting

Reference menu

Reference type

5

67

HB 13.0001-EN

3.0

The reference run to an edge as well as the above settings are clarified by examples.

Reference type ”Edge”, positive reference speed,

”Reference” as ”Active high”

Reference type ”Edge”, positive reference speed,

”Reference” as ”Active low”

Example 1

Example 2

Reference type ”Edge”, negative reference speed,

”Reference” as ”Active high”

Reference type ”Edge”, negative reference speed,

”Reference” as ”Active low”

Example 3

Example 4

Edge signal level

V

reference

Position

Edge

Starting point

Fig. 6

Examples for referencing to an edge

In example 1, referencing is carried out at a positively set reference speed with the

reference type ”Edge” to a high level of the input. At starting time, the signal on the digital

input ”Reference” is low. The drive accelerates to the reference speed and traverses in

positive direction at reference speed until the positive edge on the ”Reference” input is

reached. The 0 position is set here, and the drive is stopped.
The same preconditions apply to example 2. The level of the ”Reference” input, though, at

starting time represents the ”High” status. The drive traverses at negative speed until the

falling edge of the ”Reference” signal is recognised. After the drive is stopped and

accelerated again, it traverses over the edge at positive speed. The 0 position is set and the

drive is stopped.