HB 13.0001-EN

3.0

DC-bus voltage
The DC-bus voltage is displayed in volts and is the DC voltage required for the power

section. If the DC-bus voltage is too low, the servo inverter outputs a warning or switches

off the motor.

Device type

Voltage threshold

Warning signal (V)

Disconnection (V)

Mains voltage device 230 VAC/325 VDC

220

180

Low-voltage device 42 V

32

37

Low-voltage device 24 V

19

17

Equivalently to this, if the DC-bus voltage is exceeded, the motor at first is decelerated via

loss resistance, and in case of further voltage rise it is switched off.

Device type

Voltage threshold

Brake resistor activation (V)

Disconnection (V)

Mains voltage device 230 VAC/325 VDC

370 - 380

400

Low-voltage device 42 V

-----

52

Low-voltage device 24 V

-----

36

Tab. 1

Voltage threshold: brake resistor

Electronics temperature
This field indicates the current electronics temperature. The limit value for the

temperature of the electronics is 78°C. By means of a specific derating above 70°C, this

limit is prevented from being exceeded. During the derating, the current and therefore the

torque generated by the motor is linearly reduced from the output value to zero on the

upper limit value. As this at any rate brings about a reduced output, the derating is

displayed under a warning.

Motor temperature
Another important value is the motor temperature that is displayed here, its limit value

being 140°C. Here the motor power above 130°C is also linearly reduced by means of a

derating , at which just like in case of the electronics temperature a warning is output. If

the critical temperature limit of 140°C is reached in spite of the derating, the output stage

is switched off, and a corresponding fault message is output.

Active travel data set
Here the currently edited travel data set is shown. The possible travel data set numbers in

this connection can be 0 to 99. If currently no travel data set is being edited, the number