Software implementation and parameter setting – Lenze 931W User Manual

Page 51

Advertising
background image

Software implementation and parameter setting

Inputs and outputs menu

Digital I/Os: digital input

5

51

HB 13.0001-EN

3.0

Control via Profibus

Control via CAN bus

Control via ”Fluxx” or via digital IO

Function
Teach

By means of the ”Teach” function, the current

actual position of the drive can automatically be

transmitted as a set position of the travel data

set 0 under the following conditions:

A The controller type of travel data set 0 is

”Absolute position”

B The output stage has to be switched off

(motor at zero current)

This function can only be used in the operating

modes ”Online level 1” or ”Offline” of the Fluxx

program.

No function

No function

Stopover at zero current The current travel program is stopped if the

input is active, and the drive is decelerated to

the speed 0. Afterwards the output stage is

switched off (motor at zero current). As soon as

the input is deactivated, the output stage is

activated, and the program or the current travel

data set is continued.

No function

No function

Limit switch, left

In case of the reference type ”Limit switch, left”, the digital input is evaluated as a reference. When a

reference run is effected and the limit switch is reached, the home position is set in consideration of

the settings effected on the ”Reference” tab.

Furthermore, a quick stop is actuated if the limit switch is reached during normal operation.

Limit switch, right

In case of the reference type ”Limit switch, right”, the digital input is evaluated as a reference. When a

reference run is effected and the limit switch is reached, the home position is set in consideration of

the settings effected on the ”Reference” tab

Furthermore, a quick stop is actuated if the limit switch is reached during normal operation.

Tab. 2

Functions of the digital input