Software implementation and parameter setting

Reference menu

Speed or velocity reference

5

62

HB 13.0001-EN 3.0

5.8.2

Speed or velocity reference

The selection of the speed/velocity reference is effected at the output end in the value and

units defined by the conversions and display units. The direction and amount of the

reference speed is adjustable depending on the process and influence the course of the

referencing. More detailed information can be gathered from the individual descriptions

of the reference type.

5.8.3

Torque/force reference

The selection of the torque/force reference is effected in the value and units defined by the

conversions and display units. Limiting the reference torque is particularly required with

regard to the reference type ”Limit stop, left/right”, in order to avoid damages on the

mechanics or in the drive train. The value of the reference torque is to be selected

depending on the respective process.

5.8.4

Start reference

The definition of when the reference run is to be carried out or started is effected under

”Reference start”. The following options can be selected.

Powerup

Immediately on connection of the supply voltage (without calling up a travel data set), a

reference run in accordance with the programmed settings is automatically carried out.

First start

With regard to the first start of a travel data set, the reference run is carried out directly

before the travel data set is effected. The reference run is carried out according to the

programmed settings.

Manually

A reference run is carried out if the ”Start” key in the ”Reference” menu is pressed.

Input

The reference run is started by activating the digital input of a function module. For this,

the ”Start reference” function has to be assigned to the freely configurable input. The

reference run is effected in the programmed settings.

5.8.5

Reference type

None
In applications for which no referencing is required, the reference type ”None” is to be

selected. This setting for example is reasonable for speed-controlled systems.

Note!

If no reference run is required for the process, the following setting is

recommended:

ƒ

Absolute resolver position:

-1

ƒ

Reference start:

power up

ƒ

Reference type:

none