Software implementation and parameter setting

Inputs and outputs menu

Digital I/Os: digital output

5

52

HB 13.0001-EN 3.0

5.7.2

Digital I/Os: digital output

The digital output provided can be defined in a free manner with regard to its functions.

The output is configurable as ”Active high” or ”Active low”, the function of the output not

being dependent on the type of control (activation of the servo drive via bus, digital IOs, or

the Fluxx program). For the output, the following selectable functions are provided:

Warning

If a warning occurs, the ouput becomes active. Warning signals do not yet result

in a switch-off of the motor, but they can announce operating states which can

become critical.

Example: motor temperature > 130°C

Fault

If a fault occurs, the motor is switched off automatically, and in addition the

output is set.

Example: motor temperature > 140°C

Editing data set

The output is set as soon as a travel data set is edited, or if a travel data set

currently is in process.

Setpoint reached

Here the output is activated from the time where the setpoint specified in the

current travel data set has been reached. The type of the setpoint depends on

the controller type set in the ”Travel data sets” menu, e.g. ”Speed”.

Reference run active

Here the output indicates that the motor currently is carrying out a reference

run for protective multiple earthing of the drive.

Drive in standstill

As soon as the drive is in standstill, i. e. speed = 0 rpm, the output is activated.

Profibus active

In this case, the output activation is effected if the Profibus is activated, e.g. for

communication of the motor as a DP slave with the Profibus master.

System error

A system error occurs as soon as the amount of the system deviation is greater

than the value specified in the following error window of the ”Controller”

menu.

Motor deenergised

”Motor deenergised” means that the output stage is disconnected, i. e. a torque

no longer is available on the motor shaft.

Stopover

A stopover is characterised by an interrupted travel data set. The command for

a stopover is effected via the digital input.

Single step mode

If this configuration is used, an active output signal occurs as soon as the drive

is in single step mode. The single step mode can be activated by selecting

”Single step~On” in the upper menu bar of the user program. The second

possibility to activate single step mode is to tick the ”Single step” check box in

the ”Travel data sets” menu.

Single step pause

The pause in single step mode is displayed, which eventually is effected

automatically after completion of a travel data set in single step mode. The

start of the next travel data set is either carried out by a new start command

(Single step~Continue) in the user program, or via a digital input that is

configured by ”Single step”.

Reference set

As soon as the reference is set, the activation of the output signal is effected.

This happens after a reference run has been successfully completed. The

reference furthermore is set if no reference run has been set in the ”Reference”

menu.

Tab. 3

Functions of the digital output