4 system menu, 1 conversion, Conversion – Lenze 931W User Manual

Page 37: Software implementation and parameter setting

Advertising
background image

Software implementation and parameter setting

System menu

Conversion

5

37

HB 13.0001-EN

3.0

Engagement time
For closing (equivalent to the disengagement time for opening), the brake requires an

application time. In the engagement time, the full holding torque is positioned on the

drive, so that the position reached is also maintained during the closing process of the

brake. A minimum engagement time of 150 ms is recommended. This time is

system-dependent.

5.4

System menu

On this menu page, system units, such as conversion factors and display units, direction of

rotation of the motor shaft with regard to the setpoint of the direction of rotation and to

the limit switch are entered. Furthermore, the offset after the reference run and the type

of evaluation of the motion, i. e. a linear axis or a rotary axis, can be specified on this menu

page.

póëíÉã

5.4.1

Conversion

Depending on whether a linear axis or a rotary axis is used, here the ratio of the primary

motion (in motor revolutions, gearbox revolutions, or resolver increments) to the

secondary motion on the rotary axis (in revolutions, on the linear axis in m, dm, cm, mm,

mm) is specified. If the unit ”increments” is used, it has to be observed that 4096

increments correspond to one motor revolution or to 360°.