Software implementation and parameter setting

Inputs and outputs menu

Digital I/Os: digital output

5

53

HB 13.0001-EN

3.0

Stop!

The digital output can also be used as an input if a function module for

inverters with an IO interface is used in addition. This, for instance, is

reasonable for drive systems where 2 limit switches are to be evaluated.

Without using a function module, only the use as an output is possible! The

function module can be procured from Lenze under the designation

930FI020000 as part of the accessories.
For the use of this specific function module it is to be observed that the cycle

time of the evaluation of the two digital inputs in comparison to the usual IO

system is twice as long.

When using the 930FI020000 function module, the output can be used as a second input.

This second input is configurable as ”Active high” or ”Active low”. With regard to the

function, the same functions as to the first input can be allocated to the second input.

Stop!

An assignment of the same function to both inputs is to be avoided.