Reference menu

Reference type

5

64

HB 13.0001-EN 3.0

ƒ

During the reference run, the limit switches can additionally be evaluated. This is

recommended, as in many applications at the start of referencing it is not known in

which direction the reference switch is positioned. For activating the evaluation of

the limit switches, the ”Software limit switch” function on the ”System” tab has to

be selected.
With software limit switch: limit switches are also evaluated
Without software limit switch: limit switches are not evaluated

If a limit switch is reached in the case of an active monitoring process of the limits switches

during a reference run before the reference switch has been recognised, the reference

speed is reversed, and the search for the reference switch is continued in the opposite

direction.
If the software limit switches are used, the entered limit values (left / right) are irrelevant.

Solely the numerical values have to plausible in themselves (e.g. left limit switch < right

limit switch at positive clockwise direction of rotation).
If no limit switches are evaluated, the drive is traversed at the set reference speed if the

drive is not positioned in the area of the reference switch (see Fig. 4 example 1 and

example 2) at the start of the reference run. If the drive is positioned in the area of the

reference switch, referencing at first is carried out at negatived reference speed until the

area of the reference switch is left. Then the edge of the reference switch is traversed at the

reference speed selected, and the home position is set.
If the limit switches are evaluated, the reference run always is started at negatived

reference speed. It is only reversed when a reference switch is left (see Fig. 4 example 4) or

when a limit switch is reached (see Fig. 4 example 3). This procedure ensures that the drive

is braked and has to be accelerated in the opposite direction only once during a reference

run.
The reference run to a reference switch as well as the above settings is illustrated by means

of examples. They are shown in the Fig. 4.
For example 1, a positively set reference speed is selected, and referencing is carried out to

the edge to the high signal level. The limit switches at first are not evaluated. The drive -

as it is not positioned in the area of the reference switch at the start - traverses at the set

reference speed until the reference switch is recognised via the rising edge of the digital

input. Here, the 0 position is set. Then the drive is stopped. Example 2 shows a similar

process at negative speed.
Inexamples3 and4, thelimit switchesare evaluated.Inbothcases, thedrives aretherefore

started at the negatived reference speed. In example 4, the reference switch is recognised

and traversed. After the reference switch has been traversed, the drive is stopped and

afterwards accelerated to the defined reference speed. When the area of the reference

switch is re-entered, the 0 position is set, and afterwards the drive is stopped. In the case

of example 3, first the limit switch is reached. Here the drive reverses its direction of

rotation and traverses at the defined reference speed until the rising edge of the reference

switch is recognised.