Software implementation and parameter setting

Status menu

Warning signals

5

28

HB 13.0001-EN 3.0

5.2.3

Warning signals

The sector that is referred to as ”Warning”, in the ”Status” menu contains different

warning signals, which are explained in the following.

ƒ

DC-bus voltage underrun

The DC-bus voltage has underrun the warning value. The limit values for the warning can

be gathered from the ”Voltage threshold” table ( 23).

ƒ

Brake voltage beyond the tolerance range

The voltage for the brake is beyond the warning range that is set (delivery condition

22…26 V).

ƒ

Motor temperature exceeded

The motor temperature has exceeded 130°C. A derating is initiated.

ƒ

Electronics temperature exceeded

This warning signal indicates that the temperature of the motor electronics has exceeded

the value of 70°C and a derating is initiated.

ƒ

Following error

This warning signal indicates that the deviation between the current actual position value

and position setpoint (the following error) is greater than the following error set.

ƒ

Derating

Due to a too high temperature of the motor or the inverter, the output power of the

inverter is reduced, in order to counteract further heating.