Short setup

Short setup of a speed control

6

74

HB 13.0001-EN 3.0

6

Short setup

In the context of this paragraph, a short setup is described by means of an example. The

main focus of this chapter inthis connectionis not the mechanical or electrical installation,

but the software-controlled commissioning. For purposes of control, a speed control is

parameterised. Only the steps that are obligatory, by means of which a drive is

parameterised and commissioned, are described.
The electrical and mechanical installation of the fluxxtorque 931M and 931W drive series

is to be carried out before the short setup. More detailed information can be gathered from

the Operating Instructions.

Danger!

Observe the notes mentioned in the Operating Instructions. An incorrect

installation may bring about damage to persons and to material assets.

6.1

Short setup of a speed control

Menu

Description

Setup

Æ

Operating mode: ”Service”

In the ”Setup” menu of the fluxx program, the operating mode ”Service” is to

be selected for complete parameter setting. If a different operating mode is

selected, due to the limited authorisations, not all of the parameters listed in

the following can be changed.

Service *

Æ

Entry of the current factor

Æ

Entry of the max. motor torque

Æ

Entry of the max. motor speed

Æ

Brake available?

Æ

If required, implementation of a resolver

adjustment

Afterwards, the most important parameters of the drive are to be defined in

the ”Service” menu:

z

Setting of the current factor ( 30)

z

Setting of the max. motor torque ( 30)

z

Setting of the max. motor speed ( 30)

z

If a brake is available, the respective option is to be selected by a check

mark. Afterwards a resolver adjustment (adjusting resolver) can be effected

in the load-free state. Optionally, also the gearbox ratio (if available) can be

entered, or the fieldbus system can be parameterised. This, however, is not

obligatory for a short setup.

Status **

Æ

Check of the drive status

Æ

If required, elimination of faults

In the ”Status” menu it is to be checked whether faults are available. They for

instance can be attributed to

z

an exceeding or underrun of the permissible brake voltage

or

z

an exceeding or underrun of the permissible DC-bus voltage.

Information on the elimination of faults can be gathered from the GHB

931M/W.