Software implementation and parameter setting

Status menu

5

21

HB 13.0001-EN

3.0

5.2

Status menu

This menu page displays warning signals that do not result in a switch-off of the amplifier

output stage, fault messages which cause a switch-off of the amplifier output stage, and

status messages visualising the responses triggered by the warning signals and fault

messages, as well as general operating states. In addition, the actual values including their

units are displayed, reflecting the current physical and electrical operating states.

pн~нмл

Torque
In this field, the theoretically calculated output torque of a rotary axis, or the theoretically

calculated output force of a linear axis is displayed. The value depends on the conversions

and display units set in the ”System” menu. Furthermore there is a dependence with

regard to the gearbox ratio. Thus, this value for instance becomes greater with an

increasing reduction of the gearbox that is specified in the ”Service” menu. The efficiency

and loss factors of the connected units (gearbox, linear axes, etc.) are not considered. The

displayed value furthermore depends on the current factor that is set in the ”Service”

menu.

Speed
Depending on the conversions and display units set in the ”System” menu, here the

currently output velocity is displayed for a linear axis, and the currently output speed is

displayed for arotary axis. Thereby highgearbox ratios and gearbox reductions whichhave

been defined in the ”Service” and ”System” menus, are integrated into the calculations.