1 digital i/os:digital input, Digital i/os: digital input, Software implementation and parameter setting – Lenze 931W User Manual

Page 49

Advertising
background image

Software implementation and parameter setting

Inputs and outputs menu

Digital I/Os: digital input

5

49

HB 13.0001-EN

3.0

5.7.1

Digital I/Os: digital input

The design with a digital input and output provides one input and one output, respectively,

which can be freely assigned with regard to their functionality. The digital input as well as

the digital output is configurable as ”Active high” or ”Active low”.
The individual functions of the digital input depend on the type of control (via Fluxx or via

a bus system). The limited usability of the digital input for bus systems can be attributed

to the nonconformity (DS402, Drivecom). For the input, the following selectable functions

are provided:

Note!

For bus controlled systems it is recommended to set the function of the digital

input and digital output via the according communication objects of the

respectively used bus system (e.g. object 2006h for selecting the function of

the digital input for CANopen systems).
If the setting of the functions of the digital IOs is effected via Fluxx, after

allocating and saving the function for the digital input and output, the drive is

to be switched to a deenergised state and to be reconnected afterwards. Only

after the drive is restarted, the setting for the IOs for the bus system is

accepted!

Advertising