188

Publication 1404-UM001F-EN-P - November 2009

Appendix A Powermonitor 3000 Data Tables

Summary of Powermonitor 3000 Data Tables for all Communication Options

Data Table Name and Description

(1)

Dat

a

Acc

e

ss

Index

ed

Reads

(3)

Fi

le No.

(4

)

(DF

1,

CSP

)

Remo

te I/

O

BT Size

As

sy

Instance

(CIP

, DNet

)

Modbus

Starting

Add

ress

(6

)

No. of

Elements

Applies to

Config

ur

-

able

Refer to
Page

M4, M5

M6

M8

Remote I/O, DeviceNet, EtherNet/IP and
ControlNet I/O Messaging Parameters

R/W

-

-

I/O

1,2

-

-

(7)

• • •

(7)

191

Discrete Data Parameters

R

N9

10

3

30001

6

• • •

193

Basic Device Configuration Parameters

R/W

F10

20

4,5

40001

8 or 9

(8)

• • •

194

Date and Time Parameters

R/W

N11

12

6,7

40101

8

• • •

195

Advanced Device Configuration Parameters

R/W

N12

26

8,9

40201

26

• • •

196

Native Communication Configuration Parameters

R/W

N13

11

10,11

40301

10

(9)

• • •

198

Optional Communication Configuration Parameters

R/W

N14

24

12,13

40401

20

• • •

199

Metering Voltage, Current, and Frequency Result
Parameters

R

F15

38

14

30101

14

• • •

205

Metering Sequence Voltage, and Current Results
Parameters

R

F16

27

15

30201

11

• • •

206

Metering Power Results Parameters

R

F17

31

16

30301

13

• • •

207

Metering Demand Results Parameters

R

F18

25

17

30401

10

• • •

208

Metering Power Factor Results Parameters

R

F19

33

18

30501

13

• • •

209

Metering Real and Apparent Energy Results
Parameters

R/W

N20

29

19,20

40501

23

• • •

210

Metering Reactive Energy and Amp-hour Results
Parameters

R/W

N21

30

21,22

40601

23

• • •

211

Selftest/Diagnostic Results Parameters

R

N22

36

23

30601

27

• • •

212

DF1 PCCC Diagnostic Status Reply Parameters

R

(5)

-

-

-

-

• • •

213

Setpoint Setup/Read-back Select and Status
Parameters

R/W

N23

22

24,25

40701

16

• • •

215

Trend Log Configuration/Read-back Record Select
Parameters

R/W

N24

34

26,27

40801

26

• • •

220

Trend Log Results Parameters

R

F25

48

28

30701

14 or 22

(10)

• • •

221

Min/Max Log Configuration/Read-back Select
Parameters

R/W

N26

13

29,30

40901

9

• • •

223

Min/Max Log Results Parameters

R

F27

28

31

30801

11

• • •

227

Event Log Configuration/Read-back Record Select
Parameters

R/W

N28

9

32,33

41001

6

• • •

228

Event Log Results Parameters

R

N29

21

34

30901

14,17,18

(11)

• • •

229

User-configured Table Setup Parameters

R/W

N30

35

35,36

41101

26

• • •

233

User-configured Table Results Parameters

R

F31

62

37

31001

14 or 23

(12)

• • •

235

Write Error Status Parameters

R

N32

4

38

31101

2

• • •

236

Harmonic Analysis Configuration/Read-back Select
Parameters

R/W

N33

14

39,40

41201

9

• • •

237

Harmonic Results; THD, Crest Factor, and More
Parameters

R

F34

23

41

31201

9 or 10

(13)

• • •

238

Harmonic Results; Odd Harmonics 1…21
Parameters

R

F35

39

42

-

14

• •

239

Harmonic Results; Odd Harmonics 23…41
Parameters

R

F36

40

43

-

14

• •

240

Harmonic Results; Even Harmonics 2…20
Parameters

R

F37

41

44

-

14

• •

241

Harmonic Results; Even Harmonics 22…40
Parameters

R

F38

42

45

-

14

• •

242

Oscillograph Configuration/Read-back Data Select
Parameters

R/W

N39

15

46,47

-

11

• •

243

Advertising