Rockwell Automation 1203-CN1 ControlNet Communications Module 1203-CN1 User Manual

Page 127

Advertising
background image

Publication 1203-5.13 – February, 2002

Supported Emulated Block Transfer Commands: Product ID Number Read

F-9

Message Operation

Product ID Number Read, through the drive response message
word 3, indicates the type of device the 1203-CN1 module is
connected to. This value is defined in the message response chart
shown above.

If an error has occurred, word 1 of the response returns a negative
value of -32512.

Example

In this example, the Product ID Number Read was requested. The
drive response contained a value of 3 in word 3 of its message
response, indicating a connection to a 1336 PLUS drive.

Data File Format

* Example only - These values vary depending on parameters and products.

0

1

2

3

4

5

6

7

8

9

PLC request

3

256

0

Drive Response

6

256

0

3*