Fault queue size, Plc block transfer emulation instruction data, Message operation – Rockwell Automation 1203-CN1 ControlNet Communications Module 1203-CN1 User Manual

Page 136: Example

Advertising
background image

Publication 1203-5.13 – February, 2002

F-18

Supported Emulated Block Transfer Commands: Fault Queue Size

Fault Queue Size

Fault Queue Size gets the number of fault entries allowed in the fault
queue.

PLC Block Transfer Emulation Instruction Data

PLC request instruction length: 3 words
Drive response instruction length: 4 words

Message Operation

Fault Queue Size reads back the size of the fault queue available in
the product. Each product may have a different number of fault queue
entries available for storage.

If an error has occurred, word 1 of the response returns a value of
-30975.

Example

In this example, a 1336 PLUS drive was used. This product has a fault
queue of four storage locations available to store faults. This value is
seen in word 3 of the response header message.

Data File Format

* Example only - These values vary depending on parameters and products.

Header

Word 0

PLC Decimal Value

1793

Message Structure

Header

Word 1

Header

Word 2

PLC Request

Header Word 0

Header Word 1

Header Word 2

Message Length

Message Length

PLC Decimal Value

1793 -- Message OK

-30975 -- Message Error

0

Drive Response

3

0

5

Data

Word 3

Fault Queue Size

0

1

2

3

4

5

6

7

8

9

PLC request

3

1793

0

Drive response

6

1793

0

4*