Get_attribute_all response – Rockwell Automation 1203-CN1 ControlNet Communications Module 1203-CN1 User Manual
Page 90

Publication 1203-5.13 – February, 2002
D-4
ControlNet Objects: Class Code 0x01 — Identity Object
Get_Attribute_All Response
At the Class level the order of the attributes returned in the “Object/
service specific reply data” portion of the Get_Attribute_All response
is defined as follows:
At the instance level, the order of the attributes returned in the
“Object/service specific reply data” portion of the Get_Attribute_All
response is as follows:
Attribute ID
Definition
1
Revision (low BYTE) Default = 1.
Revision (high BYTE) Default = 0.
2
Max Instance (low BYTE) Default = 1.
Max Instance (high BYTE) Default = 0.
6
Max ID Number of Class Attributes (low BYTE) Default = 0.
Max ID Number of Class Attributes (high BYTE) Default = 0.
7
Max ID Number of Instance Attributes (low BYTE) Default = 0.
Max ID Number of Instance Attributes (high BYTE) Default = 0.
Attribute ID
Definition
1
Vendor
2
Device Type
3
Product Code
4
Major Revision
5
Status
6
Serial Number
7
Product Name Length