Computer connections – Rockwell Automation 2711PC-xxxx PanelView Plus Compact User Manual User Manual

Page 92

Advertising
background image

92

Publication 2711PC-UM001A-EN-P - March 2009

Chapter 6 Terminal Connections

Computer Connections

The RS-232 serial port on the base-configured unit of the terminals
supports:

application uploads/downloads using a direct connection.

printing.

Available Cables
Cat. No. 2711-NC13, 5 m (16.4 ft)
Cat. No. 2711-NC14, 10 m (32.7 ft)
Cat. No. 2706-NC13, 3 m (10 ft)

25-pin to 9-pin
Adapter (if required)

PanelView Plus Compact Terminals

RS-232 Port

Computer

PanelView Port (DCE)

Computer Port (DTE)

with Handshaking

9-pin male

9-pin male

1 NC

1

DCD

2

2

RXD (Data Receive)

3

3

TXD (Data Transmit)

4 NC

4

5

5

COM

6 (pulled high to +12V)

6

DSR

7

7

RTS

8

8

CTS

9 NC

9

NC

Upload/Download Cable without Hardware Handshaking

PanelView Printer Port

(DCE)

Computer Port

(DTE)

9-pin male

9-pin

25-pin

2

2

3

3

3

2

5

5

7

RXD

TXD

COM

DSR

RTS

CTS

RXD

TXD

COM

Advertising