System information data items – Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual

Page 110

Advertising
background image

4–62

OCI Data Server Data Items

Publication 8520-6.6 - August 1999

ESTOP_STATE
Data Type

USINT

Read/Write

Read only

Array Index

none

Control Type

Lathe/Mill/Grinder

1

1

Grinder Control Type is not available for Release 1 of 9/PC.

This parameter is used to identify the E–STOP status of the control.
It is updated as a foreground task on the CNC though update time to
the OCI station is still configured in AMP.

0 Indicates this CNC is in E–STOP
1 Indicates this CNC is out of E–STOP

NUM_PROCESSES
Data Type

UINT

Read/Write

Read only

Array Index

none

Control Type

Lathe/Mill/Grinder

1

1

Grinder Control Type is not available for Release 1 of 9/PC.

This parameter is used to identify the number of processes the on the
CNC. Use this data item to identify multi–process systems from
single process systems.

1 Indicates this CNC controls 1 process
2 Indicates this CNC controls 2 processes

Important: This parameter does not apply to Release 1 of the 9/PC.

VELOCITY_GAINS_FROM_TABLE, axis_num
Data Type

INT

Read/Write

Read/Write

Array Index

none

Control Type

Lathe/Mill/Grinder

1

1

Grinder Control Type is not available for Release 1 of 9/PC.

System Information Data

Items