OCI Data Server Data Items

Publication 8520-6.6 - August 1999

Value of

LINE_1_MESSAGE_DATA,2

Resulting impact to

LINE_1_MESSAGE_DATA,3:

0

NO_VARIABLE - this indicates that the third

word is not used. This means there is no acĆ

companying text for the message and there is

only one message in this base.

1

EXCLUSIVE - mutually exclusive message.

This indicates the third word of this data item

is the message index for the given base.

2

AXIS_HEAD - there is only one message in

this base The third word indicates the axis

name to be shown at the beginning of the

message.

3

AXIS_TAIL - there is only one message in

this base. The third word indicates the axis

name to be shown at the end of the message.

4

CHANNEL_HEAD - there is only one mesĆ

sage in this base. The third word indicates

the channel used to be shown at the beginĆ

ning of the message.

5

CHANNEL_TAIL - there is only one message

in this base. The third word indicates the

channel used to be shown at the end of the

message.

6

SLOT_HEAD - there is only one message in

this base. The third word indicates the ampliĆ

fier slot number to be shown at the beginning

of the message.

7

SLOT_TAIL - there is only one message in

this base. The third word indicates the ampliĆ

fier slot number to be shown at the end of the

message.

LINE_1_MESSAGE_DATA,3
This data item returns an integer that is dependent on the value of
LINE_1_MESSAGE_DATA,2. The value of
LINE_1_MESSAGE_DATA,3 is interpreted as follows:

Exclusive Number – (word two value is 1). Word 3 returns the index
of the error message in the message base. Refer to your 9/Series PAL
Reference Manual
or 9/PC Logic Interface Reference Manual
(System Error Detection chapter) for details on this error number
indexes.

Axis Name – (word two value is 2(head) or 3(tail)). Word 3 returns
a bit pattern indicating which axis is to be displayed. A one in any
bit indicates that logical axis number is to have its axis name
displayed (right most bit being axis 1). Axis names are assigned to
logical axis numbers in AMP.