OCI Data Server Data Items

Publication 8520-6.6 - August 1999

The port_id index must always be used with this data item. You can
not use this index to access more than one port per request. Data for
this item is enumerated as follows:

This Value:

Indicates/Selects

0

Odd

1

Even

2

None

For example assigning a value of 1 to the following item:

PORT_PARITY, 2

selects Even parity for port B.

PORT_STOP_BITS, port_id
Data Type

INT (enumerated)

Read/Write

Read/Write

Array Index

port_id

Control Type

Lathe/Mill/Grinder

This item is used to read/write the number of stop bits used for the
specified communication port. The index port_id identifies the port
as follows:

1 – port A
2 – port B

The port_id index must always be used with this data item. You can
not use this index to access more than one port per request. Data for
this item is enumerated as follows:

This Value:

Indicates/Selects

0

1 bit

1

1.5 bits

2

2 bits

For example assigning a value of 1 to the following item:

PORT_STOP_BITS, 2

selects 1.5 stop bits for port B.