Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual

Page 79

Advertising
background image

4–31

OCI Data Server Data Items

Publication 8520-6.6 - August 1999

HARDWARE_STATUS_PORTA
Data Type

USINT (bit pattern)

Read/Write

Read only

Array Index

none

Control Type

Lathe/Mill/Grinder

The HARDWARE_STATUS_PORTA item identifies the current
hardware status of port A. This is a bit pattern item whose bits
identify the hardware status as follows:

This

Bit:

Indicates:

0

CTS

1

RTS

2

(not used)

3

(not used)

HARDWARE_STATUS_PORTB
Data Type

USINT (bit pattern)

Read/Write

Read only

Array Index

none

Control Type

Lathe/Mill/Grinder

The HARDWARE_STATUS_PORTB item identifies the current
hardware status of port B. This is a bit pattern item whose bits
identify the hardware status as follows:

This

Bit:

Indicates:

0

CTS

1

RTS

2

DSR

3

DTR

LEVEL_2_STATUS_PORTA
Data Type

USINT (bit pattern)

Read/Write

Read only

Array Index

none

Control Type

Lathe/Mill/Grinder

The LEVEL_2_STATUS_PORTA item identifies the current data
status of communications on port A. This is a bit pattern item whose
bits identify the hardware status as follows:

Advertising