Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual
Page 77

4–29
OCI Data Server Data Items
Publication 8520-6.6 - August 1999
PORT_PROGRAM_NAME, port_id
Data Type
INT (enumerated)
Read/Write
Read/Write
Array Index
port_id
Control Type
Lathe/Mill/Grinder
This item is used to read/enable/disable the part program name on
tape feature. This feature is used for tape devices. Refer to your
operation and programming manual for details on using this feature.
The index port_id identifies the port as follows:
1 – port A
2 – port B
The port_id index must always be used with this data item. You can
not use this index to access more than one port per request. Data for
this item is enumerated as follows:
This Value:
Indicates/Selects
0
No (disabled)
1
Yes (enabled)
2
N/A
For example assigning a value of 1 to the following item:
PORT_PROGRAM_NAME, 2
enables this feature for port B. The N/A enumeration is only
available for tape devices that do not support this feature. Non-tape
devices do not have this feature.
PORT_TIMEOUT_VALUE, port_id
Data Type
INT (enumerated)
Read/Write
Read/Write
Array Index
port_id
Control Type
Lathe/Mill/Grinder
This item is used to read/write the timeout value used for the
specified communication port. The index port_id identifies the port
as follows:
1 – port A
2 – port B