Paramacro items, Part program directory items – Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual

Page 199

Advertising
background image

OCI Data Items

A–11

Publication 8520-6.6. - August 1999

Control Type

Req

Dual

Proc.

Units

Dependency

Units

Array Indices

Num

Indices

OCI/9/PC

Data Type

Description

Item (Name)

193

MEMORY_DUMP_DATA

Memory dump data

(debug monitor)

INT [ ]

OCI

1

MEM_DUMP_SIZE

No

R

All Controls

198

NUM_RING_DEVICES

Number of I/O ring devices configured

INT

OCI

No

R

All Controls

190

PAL_REVISION

PAL Symbols Revision

(debug monitor)

DINT

OCI

0

No

R

All Controls

191

PALLOC_FREE_SPACE

Available Pool Memory

(debug monitor)

DINT

Both

0

Bytes

No

R

All Controls

296

REMOTE_INPUT_DATA

Remote I/O input data ($RMI1,8)

INT [ ]

OCI

1

MAX_REMOTE_IO

No

R

All Controls

297

REMOTE_OUTPUT_DATA

Remote I/O output data ($RMO1,8)

INT [ ]

OCI

1

MAX_REMOTE_IO

No

R

All Controls

304

RING_IO_CARD_TYPE

Output data from the ring device at the requested

position

USINT [ ] [ ]

OCI

1

MAX_NUMBER_RING_DEVICES

No

R

All Controls

301

RING_IO_DEVICE_ADDRESS

Device address on the ring at the requested

position

USINT [ ]

OCI

1

MAX_NUMBER_RING_DEVICES

No

R

All Controls

302

RING_IO_DEVICE_INPUT_DATA

Input data from the ring device at the requested

position

USINT [ ]

OCI

1

MAX_NUMBER_RING_DEVICES

No

R

All Controls

303

RING_IO_DEVICE_OUTPUT_ DATA

Output data from the ring device at the requested

position

USINT [ ]

OCI

1

MAX_NUMBER_RING_DEVICES

No

R

All Controls

300

RING_IO_DEVICE_TYPE

Device type on the ring at the requested position USINT [ ]

OCI

1

MAX_NUMBER_RING_DEVICES

No

R

All Controls

356

FINE_SCAN_TIME_AVG

Average scan time for secondary interpolation UINT

9/PC

0

No

R

All Controls

357

FINE_SCAN_TIME_MAX

Maximum scan time for secondary interpolaĆ

tion

UINT

9/PC

0

No

R

All Controls

358

BLOCK_CYCLE_TIME

Average block activation interval

UINT

9/PC

0

No

R

All Controls

359

BLOCK_CYCLE_TIME_MAX

Maximum block activation interval

UINT

9/PC

0

No

R

All Controls

360

FOREGROUND_LOGIC_TIME

Average foreground logic execution interval

UINT

9/PC

0

No

R

All Controls

361

FOREGROUND_LOGIC_TIME_MAX

Maximum foreground logic execution interval

UINT

9/PC

0

No

R

All Controls

362

AMPED_FINE_SCAN_TIME

AMPed secondary interpolation rate

UINT

9/PC

0

No

R

All Controls

363

COARSE_SCAN_TIME

AMPed and computed primary interpolation

rate

UINT

9/PC

0

No

R

All Controls

n

Paramacro Items

SP.....................

Paramacro Parameters by their # numbers

LREAL [ ]

Both

Yes

R/W

All Controls

113

COM2A_PARAMETER_NAMES

Com 2A Parameters Names

STRING1 [ ]

Both

1

NUM_COM2A_PAĆ

RAMS

Yes

R/W

All Controls

o

Part Program Directory Items

42

ACTIVE_PART_PROGRAM

Active Program Name

STRING1

Both

0

Yes

R

All Controls

43

ACTIVE_SUB_PROGRAM

Active Sub-program Name

STRING1

Both

0

Yes

R

All Controls

Advertising