Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual

Page 82

Advertising
background image

4–34

OCI Data Server Data Items

Publication 8520-6.6 - August 1999

LINE_1_MESSAGE_DATA, error_integer
Data Type

UDINT

Read/Write

Read only

Array Index

error_integer

Control Type

Lathe/Mill/Grinder

1

1

Grinder Control Type is not available for Release 1 of 9/PC.

This item is used to pass the active line 1 error message from the
CNC. Refer to your operation and programming manual for details
on line one active error messages. If messages of the same priority
are active this item will change between the different messages. If a
lower priority message is active it will not be passed into this item
until the higher priority message is cleared.

Messages are returned to the OCI station as a message base, an
index, and any special characters for that message. This information
is provided using the three integer array associated with this data
item.

Important: Refer to your 9/Series PAL Reference Manual or 9/PC

Logic Interface Reference Manual, System Error
Detection chapter for tables listing bases and the
corresponding message index. Descriptions for the
error messages are available in your operation and
programming manual.

LINE_1_MESSAGE_DATA,1
This data item returns the error message base for the currently active
line one error message.

LINE_1_MESSAGE_DATA,2
This data item is an enumeration that identifies the use of the
information in the third word. It is enumerated as follows:

Advertising