Control type – Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual
Page 56

4–8
OCI Data Server Data Items
Publication 8520-6.6 - August 1999
OFFSET_NUM
This array index is dimensioned in AMP as the maximum number of
tool offsets allowed on your system.
TOOL_NUM
This array index is dimensioned in AMP as the maximum number of
tool numbers allowed on your system.
The “Control Type” attribute indicates the application(s) for which a
particular data item can be used: either:
•
Mill,
•
Lathe
•
Grinder
1
Important:
1
Grinder type control is not available for Release 1 of
the 9/PC.
The entire dual processing system is not available for Release 1 of
the 9/PC CNC. The single processing system is available on both the
9/Series and the 9/PC CNC. Some data items are not available on
the dual processing system or are not available on the single
processing system. These are indicated as:
(dual-process only) or
(single-process only)
Other data items without this designation should be assumed
available on both single and dual-processing controls (dual process is
not available for Release 1 of the 9/PC).
The control type is determined by a combination of the executive
software supplied with the control and the AMP configured control
type.
Control Type