Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual
Page 73

4–25
OCI Data Server Data Items
Publication 8520-6.6 - August 1999
PORT_DATA_BITS, port_id
Data Type
INT (enumerated)
Read/Write
Read/Write
Array Index
port_id
Control Type
Lathe/Mill/Grinder
This item is used to read/write the number of data bits used for the
specified communication port. The index port_id identifies the port
as follows:
1 – port A
2 – port B
The port_id index must always be used with this data item. You can
not use this index to access more than one port per request. Data for
this item is enumerated as follows:
This Value:
Indicates/Selects
0
7 bit
1
8 bits
For example assigning a value of 1 to the following item:
PORT_STOP_BITS, 2
selects 8 data bits for port B.
PORT_AUTO_FILENAME, port_id
Data Type
INT (enumerated)
Read/Write
Read/Write
Array Index
port_id
Control Type
Lathe/Mill/Grinder
This item is used to read/enable/disable the auto filename feature.
The auto filename feature is used for tape punch and intelligent
devices. Refer to your operation and programming manual for
details on using this feature. The index port_id identifies the port as
follows:
1 – port A
2 – port B