Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual

Page 73

Advertising
background image

4–25

OCI Data Server Data Items

Publication 8520-6.6 - August 1999

PORT_DATA_BITS, port_id
Data Type

INT (enumerated)

Read/Write

Read/Write

Array Index

port_id

Control Type

Lathe/Mill/Grinder

This item is used to read/write the number of data bits used for the
specified communication port. The index port_id identifies the port
as follows:

1 – port A
2 – port B

The port_id index must always be used with this data item. You can
not use this index to access more than one port per request. Data for
this item is enumerated as follows:

This Value:

Indicates/Selects

0

7 bit

1

8 bits

For example assigning a value of 1 to the following item:

PORT_STOP_BITS, 2

selects 8 data bits for port B.

PORT_AUTO_FILENAME, port_id
Data Type

INT (enumerated)

Read/Write

Read/Write

Array Index

port_id

Control Type

Lathe/Mill/Grinder

This item is used to read/enable/disable the auto filename feature.
The auto filename feature is used for tape punch and intelligent
devices. Refer to your operation and programming manual for
details on using this feature. The index port_id identifies the port as
follows:

1 – port A
2 – port B

Advertising