Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual

Page 80

Advertising
background image

4–32

OCI Data Server Data Items

Publication 8520-6.6 - August 1999

This

Bit:

Indicates:

This

Bit:

Indicates:

0

dc1 (receive)

4

dc1 (transmit)

1

dc2 (receive)

5

dc2 (transmit)

2

dc3 (receive)

6

dc3 (transmit)

3

dc4 (receive)

7

dc4 (transmit)

LEVEL_2_STATUS_PORTB
Data Type

USINT (bit pattern)

Read/Write

Read only

Array Index

none

Control Type

Lathe/Mill/Grinder

The LEVEL_2_STATUS_PORTB item identifies the current data
status of communications on port B. This is a bit pattern item whose
bits identify the hardware status as follows:

This

Bit:

Indicates:

This

Bit:

Indicates:

0

dc1 (receive)

4

dc1 (transmit)

1

dc2 (receive)

5

dc2 (transmit)

2

dc3 (receive)

6

dc3 (transmit)

3

dc4 (receive)

7

dc4 (transmit)

UART_MAX_BAUD_MODE
Data Type

USINT

Read/Write

Read/Write

Array Index

none

Control Type

Lathe/Mill/Grinder

Use this data item to select the maximum configured baud rate for all
devices connected to the UART port. Refer to your users manual for
details on why this baud rate needs to be selected. Setting a value of
176 selects a max baud rate of 19.2 kbaud. Setting a value to this
item at 48 selects a max baud rate of 38.4 kbaud. Values other than
176 or 48 are ignored.

Advertising