Self test numbers and descriptions – Rockwell Automation 2706-M1 MESSAGEVIEW 421 HARDWARE MANUAL User Manual

Page 119

Advertising
background image

Terminal Messages

B–3

Publication 2706-816

Terminal System Message:

Recommended Action Is:

Means:

Type:

PLC in Program Mode

Comm Status

PLC is not ready to communicate.

Set PLC to Run mode.

Value not in range

Reminder

The entered value is out of the accept-
able range.

Enter a value within the acceptable
range.

When power is first applied to the MessageView terminal or the
terminal is reset, a series of self-tests are performed. The initial
display shows copyright information and the status of the self-test
(test number). As each test is performed, its test number appears.

Self-test Number

Boot Code Version Number

Copyright, 1995

Allen-Bradley Company

V01.00 V01.00

22

Firmware
Version Number

Note: You may not see all of these test numbers during a power-up
or reset. However all tests are performed.

When all the self–tests are completed, the message Self-Tests
Complete is displayed for 2 seconds.

If a test has failed, a message is displayed showing the number of the
failed test. Note the bootcode/firmware version numbers and error
number when calling Allen-Bradley for technical support.

Error
Number

Copyright, 1995

Allen-Bradley Company

V01.00 V01.00

Error #16

See the table below for a description of the self-test numbers, and
what to do if one of the tests fails.

You can also run most of these tests using commands on the Front
Panel Editor. See Page 3–21.

Note: To reset the MessageView terminal, simultaneously press the

up arrow

, down arrow

, and Enter

keys.

Self Test Numbers and
Descriptions