Rockwell Automation 2706-M1 MESSAGEVIEW 421 HARDWARE MANUAL User Manual

Page 40

Advertising
background image

3–17

Front Panel Editor

Publication 2706–816

To specify the Simulate Start/Stop message numbers:

1. Select Simulate Parameters from the Terminal Setup submenu

and press the Enter

key. A dialog asks for the message

number the Simulate feature will start with

Simulate Message

Start

7

2. Use the up

or down

arrow keys to increment or

decrement the message number.

Or enter a message number using the numeric keypad if the
terminal is 421N or 421F.

Note: If you use the numeric keypad to enter a Start Message
number, the arrow keys work as follows:

Increments the number starting with the number you just
entered.

Deletes the last digit of the number you just entered.

3. Press the Enter

key to select the displayed Start message

number and display the ending message number entry screen.

Or press the Ack

key to return to the Terminal Setup

submenu without changing the Start message number.

Simulate Message

Stop

452

Note: In order to access the Stop message number dialog, you
must press enter while in the Start message number screen.

4. Enter the message number as in #2 above.

5. Press the Enter

key to save the message numbers and return

to the Terminal Setup submenu.

Or press the Ack

key to return to the Terminal Setup

submenu without saving anything.

6. Press the Ack

key to return to the FPE menu.

Note: In the above example, messages 7 to 452 will be simulated.