4–5

Running Applications

Publication 2706–816

Selecting a Numeric Entry Variable

A message is initially displayed with the entry variable highlighted.
If the message has more than one entry variable, the first one is
highlighted.

Use these edit keys:

To move from one entry variable to another (the cursor keys are
not used in entering values):

Up Arrow

Cursor moves left to the previous entry variable in
the displayed message.

Down Arrow

Cursor moves right to the next entry variable in the
displayed message.

To enter a value:

0

9

Numeric keys 0 through 9.

Plus/minus key.

.

Decimal point (floating positions only)

Erases the number in the highlighted entry variable

To terminate the message:

Sends the data to a controller address and
terminates the displayed message.
If a message contains more than one entry variable,
all data from the message is sent to the controller at
the same time.
Note: If no information was entered into a variable,
nothing will be sent to the controller when the Enter
key is pressed.

.

Terminates the displayed message without
transmitting the data.

To enter a numeric data entry variable:

1. Use the

or

arrow keys to highlight each data entry

variable in the message.

2. Enter a numeric value in the highlighted variable using the keys

shown above:

ENTER DESIRED

TEMPERATURE IN DEG F

Numeric entry variable
displayed here

124