4–6

Running Applications

Publication 2706–816

3. Note: If you enter a value outside the range set for that variable,

an error message appears:

Value Not in Range

Minimum = –1000

Press ACK to continue

Value Not in Range

Maximum = 100

Press ACK to continue

Press the Ack

key to clear the error message, and enter the

correct value.

4. Press the Enter

key to terminate the message and transmit its

entered data to the controller.

5. Press the Decimal Point

.

and Plus/Minus

keys to

terminate the message without saving any input data.

MessageView terminals can scale

Numeric Display variables

ASCII Display variables (if the entered data is displayed in
numeric format)

Numeric Entry variables

ASCII Entry variables (if the entered data is displayed in numeric
format)

The application program specifies if data scaling is used. The
MessageView terminal uses the following equation to scale data.

Y = mX + b

Where:

Y

= scaled display or entered value

m

= application scaling factor

X

= machine control values (raw data)

b

= application offset factor

Data Scaling