4–7

Running Applications

Publication 2706–816

Display variables

MessageView terminals provide automatic rounding and truncating
of scaled numeric data for display.

If the number of digits to the left of the decimal point fits within the
display variable field, the data is displayed with the digits to the right
truncated. For example:

Variable Field Width =

Scaled Value =

5

22.1234

Displayed Value =

22.12

If the number of digits to the left of the decimal does not fit the
display window, the terminal displays:

>>>>>>

This indicates that the data is available but is too large to fit into the
display.

For example:

Variable Field Width =

Scaled Value =

3

1234.12

Displayed Value =

>>>

For further information on scaling, see the MessageBuilder Software
manual.

Messages may be defined as acknowledgeable messages which
require operator intervention. Only one acknowledgeable message
can be displayed at a time.

Acknowledgeable messages remain displayed (active) until an

operator presses the Ack

key and the preset acknowledge hold

time (50 ms) has expired.

Pressing the Ack

key sets a momentary type bit assigned to the

message acknowledge control tag address for 50ms. The controller
program uses this tag address as an indication that an operator has
acknowledged the message.

Acknowledging